Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 662
Filter
1.
Int. j. morphol ; 41(6): 1603-1609, dic. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1528770

ABSTRACT

SUMMARY: Despite attempts to develop the plastination technique in Bolivia, standardized results have not yet been achieved that could be communicated via scientific publications. There is a great deal of misunderstanding around the technique, confusing it with classic techniques of inclusion in different types of resin, such as polyester and epoxy, but these protocols are not plastination. The aim of this work was to communicate the first standardized room-temperature plastination protocol with silicone in Bolivia, with the unique feature of doing so at the altitude of the city of La Paz, thus constituting the first communication of a plastination technique at 4,150 m.a.s.l. sub sede La Paz, La Paz, Bolivia.


En Bolivia, a pesar de los intentos en el desarrollo de la técnica de Plastinación, aún no se han alcanzado resultados estandarizados que pudieran ser comunicados por medio de publicaciones científicas. Existe una gran confusión al momento de desarrollar la técnica, confundiéndola con técnicas clásicas de inclusión en distintos tipos de reina, como poliéster y epoxy, pero no correspondiendo estos protocolos desarrollados a la técnica de plastinación. En este sentido, el objetivo de esta trabajo consistió en comunicar el primer protocolo estandarizado de plastinación a temperatura ambiente con silicona de Bolivia, con la particularidad de desarrollarlo en la altura de la ciudad de La Paz, constituyéndose, de esta manera, en la primera comunicación de una técnica de plastinación a 4.150 metros sobre el nivel del mar.


Subject(s)
Humans , Altitude , Forearm/anatomy & histology , Plastination , Hand/anatomy & histology , Silicones , Temperature , Bolivia
2.
Medisan ; 27(5)oct. 2023. ilus, tab
Article in Spanish | LILACS, CUMED | ID: biblio-1529000

ABSTRACT

Introducción: La región glútea ha sido considerada una de las zonas más observadas tanto en mujeres como en hombres y constituye un ícono representativo de belleza corporal. En los últimos años se ha incrementado el deseo de las féminas de aumentar esta región anatómica con implantes. Objetivo: Determinar los resultados estéticos de la gluteoplastia de aumento con implantes intramusculares. Métodos: Se realizó un estudio prospectivo, longitudinal y descriptivo de 25 mujeres que acudieron a la consulta externa del Servicio de Cirugía Plástica del Hospital Clínico-Quirúrgico Hermanos Ameijeiras, desde agosto de 2016 hasta febrero de 2019, para solicitar el aumento de su región glútea con implantes. Resultados: En la serie predominaron el grupo etario de 31 a 40 años (36,0 %) y el fototipo de piel III (88,0 %); asimismo, solo 6 pacientes presentaron complicaciones (24,0 %), entre las cuales sobresalieron el seroma (20,8 %), la asimetría (12,5 %) y la dehiscencia de la sutura (8,3 %). Se observó un aumento significativo de la proyección glútea después de la intervención (α=0,05) y los resultados fueron buenos en la mayoría de las integrantes de la muestra (84,0 %). Conclusiones: La gluteoplastia de aumento con implantes intramusculares es un procedimiento seguro y ofrece resultados estéticos favorables.


Introduction: Gluteal region has been considered one of the most observed areas either in women as in men and constitutes a representative icon of corporal beauty. In the last years the desire of women to increase this anatomical region with implants has been increased. Objective: To determine the aesthetic results of the augmentation gluteoplasty with intramuscular implants. Methods: A prospective, longitudinal and descriptive study of 25 women that went to the Plastic Surgery Service outpatient consultation of Hermanos Ameijeiras Clinical Surgical Hospital was carried out from August, 2016 to February, 2019, to request the increase of the gluteal region with implants. Results: In the series there was a prevalence of the 31 to 40 age group (36.0%) and the skin phototype III (88.0%); also only 6 patients presented complications (24.0%), among which seroma (20.8%), asymmetry (12.5%) and anastomotic dehiscence (8.3%) were notable. A significant increase of the gluteal projection after the intervention was observed (α =0.05) and the results were good in most of the members of the sample (84.0%). Conclusions: The augmentation gluteoplasty with intramuscular implants is a safe procedure and offers favorable aesthetic results.

3.
Arq. bras. oftalmol ; 86(4): 330-336, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447371

ABSTRACT

ABSTRACT Purpose: To evaluate the efficacy of soft HydroCone silicone hydrogel contact lenses in patients with posterior microphthalmos. Methods: The charts of 13 patients with posterior microphthalmos (26 eyes) who were fitted with soft HydroCone silicone hydrogel contact lenses were reviewed retrospectively. All the patients underwent assessments of uncorrected and best spectacle-corrected visual acuity and cycloplegic refraction. They were fitted with contact lenses according to the parameter values obtained from the topographical analysis and best contact lens-corrected visual acuity measurement. Results: The spherical equivalents of the right and left eyes ranged from 10.00 to 19.25 diopters and from 11.00 to 21.5 diopters, respectively. The mean axial and posterior chamber lengths were shorter than those of the age-matched population. However, the mean values of the anterior segment parameters such as horizontal visible iris diameter, central anterior chamber depth, lens thickness, and central corneal thickness were in the normal range. The mean keratometric measurements revealed increased corneal curvature compared with that in the normal population. The mean best contact lens-corrected visual acuity was significantly higher than the mean best spectacle-corrected visual acuity for both eyes (p=0.045). Conclusion: HydroCone silicon soft contact lenses provided better visual acuity than spectacles in the patients with posterior microphthalmos in this study.


RESUMO Objetivo: Avaliar a eficácia das lentes de contato gelatinosas HydroCone, de hidrogel com silicone, em pacientes com microftalmia posterior. Métodos: Foram revisados retrospectivamente 26 olhos com microftalmia posterior, a partir dos prontuários de 13 pacientes que receberam lentes de contato gelatinosas HydroCone, de hidrogel com silicone. Todos os pacientes foram submetidos ao exame de acuidade visual não corrigida e com melhor correção por óculos e com refração cicloplégica. Todos os pacientes receberam lentes de contato de acordo com os parâmetros obtidos na análise topográfica e foi obtida a melhor acuidade visual corrigida com lentes de contato. Resultados: O equivalente esférico do olho direito variou de 10,00 a 19,25 dioptrias, e o do olho esquerdo de 11,00 a 21,5 dioptrias. Os comprimentos médios axiais e das câmaras posteriores foram menores do que para a população de mesma idade. No entanto, os valores médios dos parâmetros do segmento anterior, como o diâmetro horizontal visível da íris, a profundidade da câmara anterior central, a espessura da lente e a espessura central da córnea estavam dentro da faixa normal. Os valores médios da ceratometria revelaram curvatura corneana aumentada em relação à população normal. A média da melhor acuidade visual corrigida com lentes de contato foi significativamente maior que a média da melhor acuidade visual corrigida com óculos em ambos os olhos (p=0,045). Conclusão: As lentes de contato gelatinosas de silicone HydroCone proporcionam melhor acuidade visual que óculos em pacientes com microftalmia posterior.

4.
Indian J Ophthalmol ; 2023 Jun; 71(6): 2466-2468
Article | IMSEAR | ID: sea-225081

ABSTRACT

Purpose: To derive a formula for accurate axial length (AL) assessment using routine ultrasound in silicone oil?filled eyes, where optical biometry is unavailable or not possible. Methods: This was a prospective, consecutive, nonrandomized study of 50 eyes of 50 patients conducted in a tertiary care hospital in North India. AL measurements were taken using both manual A?scan and IOL master, both in silicone oil?filled status and 3 weeks after silicone oil removal. A correction factor of 0.7 was used for AL adjustment in oil?filled eyes. The corrected AL (cAL) was compared with IOL master values in oil?filled eyes. Agreement analysis was carried out using Bland Altman plot. Linear regression analysis was done using uncorrected manual AL to find a new equation. Data was analyzed using Stata 14. A P value <0.05 was taken as significant. Results: The study included 40 males and 10 females, with an age range of 6–83 years (mean 41.9 years). The mean AL of the oil?filled eye as measured by manual A?scan was 31.76 mm ± 3.09 and by IOL master was 24.7 mm ± 1.74. Linear regression analysis was performed in randomly selected 35 eyes of the observed data to obtain a new equation: predicted AL (PAL) = 14 + 0.3 × manual AL. The mean difference between PAL and optically measured AL with silicone oil in situ was 0.98 ± 1.67. Conclusion: We propose a new formula for better prediction of the correct AL in silicone oil?filled eyes using ultrasound?based AL measurement.

5.
Arq. bras. oftalmol ; 86(3): 223-231, May 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439379

ABSTRACT

ABSTRACT Purpose: To compare viscotrabeculotomy with anterior chamber irrigation to Ahmed glaucoma valve implantation for secondary glaucoma following silicone oil removal. Methods: A prospective study was conducted on 43 vitrectomized pseudophakic eyes with persistent glaucoma after silicone oil removal. Patients were randomized to either viscotrabeculotomy with anterior chamber irrigation or Ahmed glaucoma valve implantation. All patients were examined on day 1, week 1, and months 1, 3, 6, 9, 12, 18, and 24 postoperatively. Postoperative complications were noted. Success was defined as an intraocular pressure between 6 and 20 mmHg and with an intraocular pressure reduction of >30% compared with the preoperative intraocular pressure. Results: There were 22 eyes in the viscotrabeculotomy with anterior chamber irrigation and 21 eyes in the Ahmed glaucoma valve implantation group. The mean preoperative and postoperative intraocular pressure in the viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation groups were 35.5 ± 2.6 mmHg and 35.5 ± 2.4 mmHg and 16.9 ± 0.7 mmHg and 17.9 ± 0.9 mmHg respectively (p˂0.0001). There was a statistically significant intraocular pressure reduction at all follow-up time points compared to preoperative values (p˂0.0001) in both groups. The unqualified success rate in the viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation groups were 72.73% and 61.9%, respectively. A minimal self-limited hyphema was the most common complication. Conclusions: Both viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation are effective in lowering the intraocular pressure in glaucoma after silicone oil removal with viscotrabeculotomy with anterior chamber irrigation providing greater reduction, higher success rates, and minimal complications.


RESUMO Objetivo: Comparar a viscotrabeculotomia com irrigação da câmara anterior com o implante de válvula de glaucoma de Ahmed para glaucoma secundário após remoção de óleo de silicone. Métodos: Foi realizado um estudo prospectivo de 43 olhos pseudofácicos vitrectomizados com glaucoma persistente após a remoção de óleo de silicone. Os pacientes foram randomizados para viscotrabeculotomia com irrigação da câmara anterior ou implante de válvula de Ahmed. Todos os pacientes foram examinados no primeiro dia, na primeira semana e 1, 3, 6, 9, 12, 18 e 24 meses após a cirurgia. Observaram-se complicações pós-operatórias. O sucesso foi definido como uma pressão intraocular entre 6 e 20 mmHg e uma redução da pressão intraocular >30% em comparação com a pressão intraocular pré-operatória. Resultados: Foram designados 22 olhos para o grupo da viscotrabeculotomia com irrigação da câmara anterior e 21 olhos para o grupo do implante de válvula de Ahmed. A pressão intraocular média pré-operatória foi de 35,5 ± 2,6 mmHg para o grupo da viscotrabeculotomia com irrigação da câmara anterior e pós- e de 35,5 ± 2,4 mmHg no grupo do implante de válvula de Ahmed. e Os valores pós-ope­ratórios foram de 16,9 ± 0,7 mmHg e 17,9 ± 0,9 mmHg para esses mesmos grupos, respectivamente (p<0,0001). Ambos os grupos tiveram uma redução estatisticamente significativa da pressão intraocular em relação aos valores pré-operatórios (p<0,0001) em todos os momentos do acompanhamento. A taxa de sucesso não qualificado nos grupos da viscotrabeculotomia com irrigação da câmara anterior e do implante de válvula de Ahmed foi de 72,73% e 61,9%, respectivamente. A complicação mais comum foi o hifema, autolimitado e mínimo. Conclusões: Tanto a viscotrabeculotomia com irrigação da câmara anterior quanto o implante de válvula de Ahmed são eficazes na redução da pressão intraocular no glaucoma após injeção de óleo de silicone, mas a viscotrabeculotomia com irrigação em câmara anterior proporcionou maior redução da pressão intraocular e maiores taxas de sucesso, com complicações mínimas.

6.
Colomb. med ; 54(1)mar. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1534280

ABSTRACT

Case description: A 42-year-old woman with severe pulmonary and mediastinal inflammatory involvement, secondary to infiltration of a silicone-related allogenic material with systemic migration. Clinical findings: The patient developed esophageal and bronchial stenosis, recurrent infections, malnutrition, and respiratory deterioration, making surgical removal of the allogenic material impossible. Treatment and outcome: Clinical and radiological improvement was achieved after treatment with multiple intravenous and oral immunomodulators. Clinical relevance: Autoimmune/inflammatory syndrome induced by adjuvants (ASIA) is a heterogeneous disease resulting from exposure to allogenic substances in a susceptible subject. These substances cause autoimmune or autoinflammatory phenomena. Since ASIA was described ten years ago, its diagnostic criteria are still under discussion, with an uncertain prognosis. The ideal therapy is based on eliminating the causative substance, but this is not always possible. Therefore, it is necessary to start an immunomodulatory treatment, using it in this patient, a scheme that had not been previously reported in the literature.


Descripción del caso: Mujer de 42 años con compromiso inflamatorio pulmonar y mediastinal severo, secundario a infiltración de un material alogénico relacionado con la silicona con migración sistémica. Hallazgos clínicos: La paciente desarrolló estenosis esofágica y bronquial, infecciones recurrentes, desnutrición y deterioro respiratorio, imposibilitando la extracción quirúrgica del material alogénico. Tratamiento y resultado: Mejoría clínica y radiológica lograda tras un tratamiento con múltiples inmunomoduladores intravenosos y orales. Relevancia clínica: El síndrome autoinmune / inflamatorio inducido por adyuvantes (ASIA) es una enfermedad heterogénea que resulta de la exposición a sustancias alógenas en un sujeto con susceptibilidad genética. Estas sustancias inducen fenómenos autoinmunitarios o autoinflamatorios. Desde que ASIA fue descrito hace 10 años, sus criterios diagnósticos continúan en discusión, con un pronóstico incierto. El tratamiento idóneo se basa en eliminar la sustancia causante, pero no siempre es posible, por lo cual se hace necesario iniciar un tratamiento inmunomodulador, empleándose en esta paciente un esquema que no había sido reportado previamente en la literatura.

7.
Indian J Ophthalmol ; 2023 Feb; 71(2): 595-600
Article | IMSEAR | ID: sea-224851

ABSTRACT

Purpose: Our aim was to determine the various risk factors for secondary ocular hypertension (OHT) following pars plana vitrectomy (PPV) with silicone oil (SO) injection. Methods: A prospective cohort study was performed on 46 eyes of 42 patients who underwent PPV with SO injection under a single surgeon between January 2020 and July 2021. Complete ophthalmological examination including gonioscopy and Goldmann applanation tonometry was performed preoperatively and on three postoperative visits, that is, day 7, day 30, and day 90. Axial length and lens thickness were measured at baseline using immersion A?scan. Anterior segment optical coherence tomography (OCT) was used for measuring anterior chamber depth (ACD) at baseline and at 3 months. Results: There was a statistically significant increase in intraocular pressure (IOP) (>21 mmHg) on day 7 (4.70 ± 7.754 mmHg), day 30 (5.24 ± 7.481 mmHg), and day 90 (2.39 ± 5.659 mmHg) (P<0.01 for all). Age <50 years, rhegmatogenous retinal detachment (RRD), and pseudophakia had a strong association with short?term OHT on day 7. Preexisting glaucoma was the only independent risk factor for long?term OHT (day 90). Higher baseline IOP and SO emulsification also contributed to long?term OHT. Conclusion: There was a statistically significant elevation in IOP at all postoperative visits. Short?term OHT was associated with younger age (<50 years), RRD, and pseudophakia. Patients with emulsified SO in the anterior chamber, higher baseline IOP, and preexisting glaucoma were at higher risk for long?term OHT.

8.
Horiz. meÌud. (Impresa) ; 23(1)ene. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1430480

ABSTRACT

El compromiso del parénquima pulmonar secundario a la inyección subcutánea de geles de silicona es un cuadro de presentación excepcional, que se presenta con mayor frecuencia en mujeres entre los 22 a 55 años. Aunque se han planteado distintas teorías sobre su etiología, esta se desconoce y puede presentar complicaciones locales, sistémicas e incluso tener un desenlace fatal. Son pocos los casos reportados en América del Sur, y en el Perú no existe reporte alguno de esta singular entidad. Se presenta el caso de un paciente varón de 28 años, transexual, previamente sano, quien tras la inyección subcutánea de geles de silicona en la región glútea, en forma ilegal y por una persona que no es profesional de la salud, manifestó, dentro de las primeras 24 horas, un cuadro clínico caracterizado por dificultad respiratoria progresiva y dolor torácico punzante de aproximadamente 7 de 10 en la escala del dolor. Al ingresar a emergencias se evidenció de manera objetiva insuficiencia respiratoria, ya que el paciente presentó una saturación de oxígeno del 72 % a Fio₂: 21 %, asimismo, el compromiso del parénquima pulmonar tanto en la tomografía y radiografía de tórax con signos muy sugerentes de esta patología. Mediante la prueba ARN para SARS-CoV-2 en la muestra respiratoria por RT-PCR en tiempo real se descartó la neumonía secundaria al virus SARS-CoV-2, igualmente se excluyó la patología por inmunosupresión y tromboembolismo pulmonar. Debido a que no existe un tratamiento estandarizado se le brindó las medidas de soporte pertinentes, tales como administración de oxígeno suplementario a bajo flujo por cánula binasal, corticoides sistémicos vía endovenosa, además de antibioticoterapia, y se logró una evolución favorable con resolución del cuadro clínico inicial. Después de 10 días de tratamiento intrahospitalario el paciente fue dado de alta.


Pulmonary parenchymal involvement secondary to the subcutaneous injection of silicone gels is an unusual condition which occurs more frequently in women aged between 22 and 55 years. Although different theories have been put forward about its etiology, it is unknown and the condition may cause local and systemic complications and even have a fatal outcome. Few cases have been reported in South America and there is no report of this unique entity in Peru. We present the case of a previously healthy 28-year-old male transgender patient who, after an illegal subcutaneous injection of silicone gels in the gluteal region given by a non-healthcare professional, showed progressive respiratory distress and stabbing chest pain of approximately 7 out of 10 on the pain scale within the first 24 hours. Upon admission to the emergency room, respiratory failure was objectively evidenced since the patient had an oxygen saturation of 72 % at a FiO₂ of 21 %, as well as pulmonary parenchymal involvement both in the CT scan and chest X-ray with signs highly suggestive of this pathology. Using a SARS-CoV-2 RNA real-time RT-PCR test performed on a respiratory specimen, COVID pneumonia, immunodeficiency disorders and pulmonary embolism were ruled out. Since there is no standard treatment, the patient was given relevant support measures such as the administration of supplemental oxygen at a low flow rate by binasal cannula, intravenous systemic corticosteroids and antibiotic therapy, thus achieving good progress with resolution of the initial clinical presentation. Then, after 10 days of intrahospital treatment, the patient was discharged.

9.
Journal of Medical Biomechanics ; (6): E135-E141, 2023.
Article in Chinese | WPRIM | ID: wpr-987926

ABSTRACT

Objective To investigate the effect of different coating methods on production quality of complex and flexible silicone vascular replicas. Methods Based on models of anterior communicating artery aneurysms, several patient-specific models were made by using spray-coating method and brush-spin-coating method respectively, and two methods for making the same vascular structure were quantitatively compared in terms of thickness growth, circumferential uniformity and light transmittance. Results Brush-spin-coating method was better than spray-coating method in the thickness control and coating uniformity for fabrication of vessels with large curvature, variable diameter and straight tube, and the model had preferably light transmittance and surface smoothness. The relative deviation of thickness by brush-spin-coating method was decreased by 8. 9% , 10. 8% and 16. 9% respectively compared with spray-coating method. Conclusions At present stage, the brush-spin coating method has the advantage of thickness uniformity and light transmittance over the spray-coating method in making silicone phantoms, and it has promising application prospects in fluid mechanics field of in vitro experiment on large vessels.

10.
Journal of Southern Medical University ; (12): 783-792, 2023.
Article in Chinese | WPRIM | ID: wpr-986989

ABSTRACT

OBJECTIVE@#To prepare customized porous silicone orbital implants using embedded 3D printing and assess the effect of surface modification on the properties of the implants.@*METHODS@#The transparency, fluidity and rheological properties of the supporting media were tested to determine the optimal printing parameters of silicone. The morphological changes of silicone after modification were analyzed by scanning electron microscopy, and the hydrophilicity and hydrophobicity of silicone surface were evaluated by measuring the water contact angle. The compression modulus of porous silicone was measured using compression test. Porcine aortic endothelial cells (PAOECs) were co-cultured with porous silicone scaffolds for 1, 3 and 5 days to test the biocompatibility of silicone. The local inflammatory response to subcutaneous porous silicone implants was evaluated in rats.@*RESULTS@#The optimal printing parameters of silicone orbital implants were determined as the following: supporting medium 4% (mass ratio), printing pressure 1.0 bar and printing speed 6 mm/s. Scanning electron microscopy showed that the silicone surface was successfully modified with polydopamine and collagen, which significantly improved hydrophilicity of the silicone surface (P < 0.05) without causing significant changes in the compression modulus (P > 0.05). The modified porous silicone scaffold had no obvious cytotoxicity and obviously promoted adhesion and proliferation of PAOECs (P < 0.05). In rats bearing the subcutaneous implants, no obvious inflammation was observed in the local tissue.@*CONCLUSION@#Poprous silicone orbital implants with uniform pores can be prepared using embedded 3D printing technology, and surface modification obviously improves hydrophilicity and biocompatibility of the silicone implants for potential clinical application.


Subject(s)
Animals , Rats , Swine , Silicon , Orbital Implants , Endothelial Cells , Porosity , Silicones , Printing, Three-Dimensional
11.
Chinese Journal of Medical Instrumentation ; (6): 383-390, 2023.
Article in Chinese | WPRIM | ID: wpr-982250

ABSTRACT

The patient-specific aortic silicone model was established based on CTA data. The digital particle image velocimetry (DPIV) test method in the modified ViVitro pulsatile flow system was used to investigate the aortic hemodynamic performance and flow field characteristics before and after transcatheter aortic valve replacement (TAVR). The results showed that the hemodynamic parameters were consistent with the clinical data, which verified the accuracy of the model. From the comparative study of preoperative and postoperative effective orifice area (0.33 cm2 and 1.78 cm2), mean pressure difference (58 mmHg and 9 mmHg), percentage of regurgitation (52% and 8%), peak flow velocity (4.60 m/s and 1.81 m/s) and flow field distribution (eccentric jet and uniform jet), the immediate efficacy after TAVR is good. From the perspective of viscous shear stress and Reynolds shear stress, the risk of hemolysis and thrombotic problems was low in preoperative and postoperative patient-specific models. This study provides a set of reliable DPIV testing methods for aortic flow field, and provides biomechanical basis for the immediate and long-term effectiveness of TAVR from the perspective of hemodynamics and flow field characteristics. It has important application value in clinical diagnosis, surgical treatment and long-term evaluation.


Subject(s)
Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Heart Valve Prosthesis , Hemodynamics , Aortic Valve Stenosis/diagnosis , Treatment Outcome
12.
Philippine Journal of Ophthalmology ; : 24-28, 2023.
Article in English | WPRIM | ID: wpr-984185

ABSTRACT

Objective@#This small case series demonstrated pars plana vitrectomy and silicone tamponade without internal limiting membrane (ILM) peeling to be a simple, safe, and effective surgical technique for the treatment of myopic traction maculopathy (MTM).@*Methods@#This is a small case series consisting of 3 eyes with MTM. In all eyes, pars plana vitrectomy with silicone oil tamponade was performed by a single vitreoretinal surgeon. Functional and anatomic outcomes are reported.@*Results@#All 3 eyes had improved visual acuity with no noted short-term complications such as iatrogenic macular hole and retinal detachment. Although foveoschisis was only partly anatomically resolved in 2 out of the 3 cases, functional outcome, in terms of visual acuity at last visit, was satisfactory.@*Conclusion@#Vitrectomy with silicone oil tamponade without ILM peeling is a simple, effective, and safe optional surgical technique to treat MTM.

13.
Arq. bras. oftalmol ; 86(6): e2021, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520198

ABSTRACT

ABSTRACT Purpose: Since particles are released in syringes during intravitreal injections, we assessed them quantitatively after agitating syringes commonly used for intravitreal injections. Methods: With and without agitation, the SR 1-ml insulin, Becton-Dickinson Ultra-Fine 0.3-ml Short Needle with a half-unit scale, HSW Norm-Ject Tuberculin, and Becton-Di­ckinson 1-ml Luer Lok Tip were examined with buffer and bevacizumab, aflibercept, and ziv-aflibercept. Flow imaging microscopy was performed to assess the particle numbers, concentrations, morphology, and size distribution. Results: Using the Becton-Dickinson Ultra-Fine syringe, the average particle count after agitation was higher than in the no-agitation group. For particles greater than 10 and 25 µm, differences were observed using the SR syringe between the two studied conditions. There were no significant differences in the means for the other syringes. Without agitation, the SR syringe had the highest number of particles (2,417,361.7 ± 3,421,575.5) followed by the Becton-Dickinson Ultra-Fine with 812.530,9 ± 996.187,2. The Becton-Dickinson Luer Lok Tip and HSW Norm-Ject performed equally with 398,396.8 ± 484,239.2 and 416,016.4 ± 242,650.1 particles, respectively. Conclusions: Flicking syringes to eliminate air bubbles results in increased numbers of particles released during intravitreal injections into the human vitreous.


RESUMO Objetivo: Visto que partículas são liberadas nas seringas durante as injeções intravítreas (IVIs), estas foram avaliadas quantitativamente após a agitação das seringas mais comumente usadas para injeções intravítreas. Métodos: A seringa SR de 1 ml de insulina, a agulha curta Becton-Dickinson Ultra-Fine 0,3 ml com escala de meia unidade, HSW Norm-Ject Tuberculin e a Becton-Dickinson Luer Lok Tip de 1 ml foram estudadas com placedo e com bevacizumabe, aflibercept e ziv-aflibercept, com e sem agitação. MicroFlow Imaging Mi­croscopy foi realizada para avaliar o número de partículas, con­centração, morfologia e distribuição das mesmas por tamanho. Resultados: A contagem média de partículas após agitação foi maior do que no grupo sem agitação usando a seringa Becton-Di­ckinson Ultra-Fine. Diferenças foram observadas usando a seringa SR entre as duas condições estudadas para partículas maiores que 10 e 25 µm. Para as demais seringas, não foram observadas diferenças significativas nas médias. A seringa SR apresentou o maior número de partículas sem agitação (2.417.361,7 ± 3.421.575,5) seguida da Becton-Dickinson Ultra-Fine com 812.530,9 ± 996.187,2. A BD Luer Lok Tip e a HSW Norm-Ject se comportaram de forma semelhante com 398.396,8 ± 484.239,2 e 416.016,4 ± 242.650,1 partículas, respectivamente. Conclusões: Agitar seringas para remover bolhas de ar resulta em um maior número de partículas liberadas durante Becton-Dickinson no vítreo humano.

14.
Rev. chil. enferm. respir ; 39(2): 169-174, 2023. ilus
Article in Spanish | LILACS | ID: biblio-1515116

ABSTRACT

La neumonía organizada es una entidad poco frecuente, caracterizada por la formación de conglomerados fibroblásticos intraalveolares conocidos como cuerpos de Masson, que puede ser criptogénica o secundaria a una respuesta inmunitaria a diversos estímulos, tales como enfermedades hematológicas, autoinmunitarias, exposición a sustancias químicas, fármacos, tóxicos, etc. Detectada y tratada de forma precoz, suele tener una buena respuesta a la corticoterapia, aunque si se diagnostica de forma tardía, la afectación pulmonar puede ser extensa, y, además, si el estímulo antigénico persiste, la respuesta al tratamiento será incompleta. Presentamos el caso clínico de una paciente de 65 años de edad quien hace 18 meses aproximadamente presentó la rotura intracapsular de sus implantes mamarios, 27 años después de su colocación. Con el mismo tiempo de evolución ha desarrollado progresivamente disnea, tos seca y dolor inframamario, habiendo llegado al diagnóstico de neumonía organizada bilateral difusa, asociada a dicha rotura de implantes.


Organizing pneumonia is a rare entity, characterized by the formation of intraalveolar fibroblastic conglomerates known as Masson bodies, which may be cryptogenic or secondary to an immune response to various stimuli, such as hematological, autoimmune diseases, exposure to chemical substances, drugs, toxics, etc. If it is detected and treated early, it usually has a good response to corticosteroid therapy, although if it is diagnosed late, the lung involvement can be extensive, and furthermore, if the antigenic stimulus persists, the response to treatment will be incomplete. We present the clinical case of a 65-year-old patient who had intracapsular rupture of her breast implants approximately 18 months ago, 27 years after their placement. With the same evolution time, she progressively developed dyspnea, dry cough and under mammary pain, having reached the diagnosis of diffuse bilateral organizing pneumonia, associated with implant rupture.


Subject(s)
Humans , Female , Aged , Prosthesis Failure , Breast Implants/adverse effects , Organizing Pneumonia/etiology , Rupture , Silicones , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Organizing Pneumonia/therapy , Organizing Pneumonia/diagnostic imaging
15.
RGO (Porto Alegre) ; 71: e20230007, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1431164

ABSTRACT

ABSTRACT Objective: To evaluate the dimensional change of edentulous models made of high density laboratory silicones at different storagetimes. Methods: A metallic master model simulating an edentulous maxilla was used. The model had projections of 1.8 cm located in the regions of canines (A and B) and molars (C and D) allowing the linear measurement of distances AB, BC, CD, DA, AC and BD. A laboratory silicone mold was made for duplication of master model in the following materials (n = 10): G1: Zetalabor 85, G2: Titanium 95, G3: Platinum 95 and G4: Gypsum type III (control). The samples were photographed and measured using a software (Image J) at times T1 (baseline) and T2 (after one week of models fabrication). The data were statistically analyzed using Kruskal- Wallis and Dun non-parametric tests (α = 0.05). Results: The storage time influenced the behavior of the materials evaluated. All groups presented dimensional changes in both times and the group Tit95 presented the best results. Only Zet85 group showed a different behavior related to the region of the model. Conclusions: The high density laboratory silicones showed satisfactory results when compared to the gypsum group. Tit95 was the most stable material and it can be recommended as an edentulous model for total protheses.


RESUMO Objetivo: Avaliar a alteração dimensional de modelos edêntulos fabricados em silicone laboratorial de alta densidade em diferentes tempos de armazenagem. Métodos: Um modelo mestre metálico simulando uma maxila edêntula foi utilizado. O modelo possuía projeções oclusais de 1,8 cm localizadas nas regiões de caninos (A e B) e molares (C e D), permitindo a mensuração das distâncias lineares AB, BC, CD, DA, AC e BD. Um molde foi fabricado em silicone laboratorial para duplicação do modelo mestre com os seguintes materiais (n = 10): G1: Zetalabor 85, G2: Titanium 95, G3: Platinum 95 e G4: Gesso tipo III (controle). As amostras foram fotografadas e mensuradas com auxílio de um software (Image J) nos tempos T1 (baseline) e T2 (após uma semana de confecção). Os dados obtidos foram avaliados estatisticamente utilizando os testes não paramétricos de Kruskal- Wallis e Dunn (α = 0.05). Resultados: O tempo de armazenagem influenciou o comportamento dos materiais avaliados. Todos os grupos apresentaram alterações dimensionais em ambos os temos de avaliação e o G2 apresentou os melhores resultados. Apenas o grupo G1 mostrou alteração dimensional dependente da região mensurada. Conclusão: Silicones laboratoriais de alta densidade mostraram resultados satisfatórias de alteração dimensional quando comparados ao gesso tipo III. O material Titanium 95foi o mais estável e pode ser recomendado como alternativa para a confecção de modelos edêntulos.

16.
International Eye Science ; (12): 1208-1210, 2023.
Article in Chinese | WPRIM | ID: wpr-976497

ABSTRACT

AIM: To observe the clinical effect of foldable capsular vitreous body(FCVB)implantation on ocular trauma and silicone oil-dependent eyes.METHODS: A prospective case study was performed on 17 cases(17 eyes)with ocular trauma and silicone oil-dependent in the First Hospital of Changsha from October 2017 to April 2022. All patients underwent FCVB or silicone oil removal combined with FCVB implantation. The follow-up time was 6mo, and the visual acuity, intraocular pressure, ocular axes, normal external appearances and FVCB were observed at 1wk and 6mo after operation.RESULTS: Only 6 cases had visual acuity before operation, and there were no statistical differences in the visual acuity before and at 1wk and 6mo after operation(P&#x003E;0.05). The intraocular pressure was low before operation, but it was elevated at 1wk and 6mo after operation. The axial length was unchanged at 1wk and 6mo after operation, and the appearance and structure of eyeball were well maintained, and FCVB was stable with no atrophy during the follow-up period.CONCLUSIONS: FCVB implantation can preserve the appearance of eyeball, and avoid atrophy of eyeball and repeated operation, which has favorable clinical application value in the treatment of ocular trauma and silicone oil-dependent eyes.

17.
Philippine Journal of Ophthalmology ; : 87-90, 2023.
Article in English | WPRIM | ID: wpr-1003662

ABSTRACT

Objective@#We report a case of a scleral buckle mimicking an orbital tumor 28 years after a retinal detachment repair.@*Methods@#This is a case report.@*Results@#A 75-year-old male consulted for progressive, painless blurred vision of the right eye. He had a history of scleral buckling surgery for retinal detachment on the right eye in 1990 that restored his vision. Examination showed right eye ophthalmoplegia and inferior displacement of the globe. Imaging revealed a right supero-temporal orbital mass. Excision of the encapsulated mass was performed. Histopathology revealed an acellular, amorphous, granular and eosinophilic material with no evidence of malignancy. These were consistent with a foreign body. Postoperatively, there were improvements in ocular motility and hypoglobus.@*Conclusion@#In patients who present with limited ocular motility and have undergone scleral buckling, hydrogel scleral buckle overexpansion should be considered. Excision of such implants is warranted to resolve the signs and symptoms and confirm the etiology.


Subject(s)
Retinal Detachment , Scleral Buckling
18.
Chinese Journal of Medical Aesthetics and Cosmetology ; (6): 11-14, 2023.
Article in Chinese | WPRIM | ID: wpr-995893

ABSTRACT

Objective:To investigate the diagnostic value of X-ray mammography, ultrasound and MRI in breast cancer with silicone implants.Methods:The clinical and imaging data of 20 patients with breast cancer in women with silicone implants in the First Affiliated Hospital of Zhengzhou University from March 2014 to October 2021 were analyzed retrospectively. The mammography, ultrasound and MRI findings were analyzed, and the differences in detection rate, diagnostic accuracy and omission diagnostic rate of breast cancer in women with implants were compared among the three imaging methods.Results:Compared with mammography, both ultrasound and MRI were able to display the prosthesis and breast lesions completely. There were significant differences in detection rate, diagnostic accuracy and omission diagnostic rate among mammography, ultrasound and MRI. And the detection rate and diagnostic accuracy of MRI in breast cancer in women with implants were higher than those of mammography, and the omission diagnostic rate was lower.Conclusions:Ultrasound and MRI are superior to mammography in evaluating breast cancer after silicone prosthesis implantation, and MRI has more advantages in guiding clinical diagnosis and treatment.

19.
Rev. cuba. oftalmol ; 35(4)dic. 2022.
Article in Spanish | LILACS, CUMED | ID: biblio-1441771

ABSTRACT

La silicona líquida es usada intravítrea cuando se requiere un taponamiento prolongado intraocular para mantener la retina aplicada. A pesar de sus ventajas, su uso se ha asociado a algunas complicaciones como catarata, queratopatía, hipertensión ocular, glaucoma entre otras. La hipertensión ocular secundaria por aceite de silicona aparece por varios mecanismos, la migración de partículas a la malla trabecular junto con el proceso inflamatorio que genera es un reto para los cirujanos, de ahí los diferentes criterios de tratamiento que existen para su completa resolución. A continuación, se presenta un paciente operado de desprendimiento de retina recidivado con hipertensión ocular secundario a aceite de silicona 9 meses después de su primera intervención. Llevó tratamiento con hipotensores oculares tópicos, orales y no resolvió por lo que se decide realizar ciclocrioterapia en dos cuadrantes. A pesar que este tratamiento no es el de elección en estos casos, podemos decir que en este paciente se logra controlar la presión intraocular luego de una sola sesión(AU)


Liquid silicone is used intravitreally when prolonged intraocular insulation is required to keep the retina applied. Despite its advantages, its use has been associated with some complications such as cataract, keratopathy, ocular hypertension, glaucoma, among others. Secondary ocular hypertension due to silicone oil appears by several mechanisms. The migration of particles to the trabecular meshwork, together with the inflammatory process it generates, represents a challenge for surgeons, hence the different treatment criteria that exist for its complete resolution. The following is a patient operated on for recurrent retinal detachment with ocular hypertension secondary to silicone oil 9 months after the first operation. He was treated with topical and oral ocular hypotensors and it did not resolve, so it was decided to perform cyclocriotherapy in two quadrants. Although this treatment is not the treatment of choice in these cases, we can say that in this patient intraocular pressure control was achieved after only one session(AU)


Subject(s)
Humans , Cataract/complications , Silicone Oils/therapeutic use , Retinal Detachment/etiology , Ocular Hypertension , Glaucoma/complications
20.
Braz. j. oral sci ; 21: e225757, jan.-dez. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1366215

ABSTRACT

Aim: This study aimed to evaluate the effect of frozen storage on the physical properties of a silicone-based test food material, highly used to evaluate the masticatory performance in research settings. Methods: A total of 1,666 silicone cubes of Optosil Comfort® with 5.6-mm edges were shaped and stored at -18°C. The cubes were subsequently tested for flexural strength (maximum force, displacement, stress, and strain) before breaking (n = 136), changes in weight and size (n = 170), and masticatory performance (n = 1360) at eight timepoints: immediately after cube preparation (baseline, no freezing), and 1, 2, 3 and 4 weeks, and 2, 4 and 6 months after frozen storage. The cubes were thawed 8 h before each assessment. Results: The maximum force, stress, maximum displacement, and deformation values for the cubes were not affected by freezing (P > 0.05). At all of the time points, the cubes exhibited similar weight (P = 0.366) and size (identical values). The masticatory performance for the cubes also showed no differences from baseline through 6 months (P = 0.061). Conclusion: Freezing Optosil Comfort® silicone cubes did not alter the physical and mechanical properties of the material, being suitable to optimize the assessment of masticatory parameters for research purposes


Subject(s)
Humans , Male , Adult , Silicone Elastomers , Materials Testing/methods , Freezing , Flexural Strength , Mastication , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL